Manufacturer: TES
Model: AVM-305
Original: Taiwan
Ideal for
-Ventilation survey
-Air-conditioning / Heating
-Sports recreational
Features
-Sensitive for low air velocity
-Ergonomic Design
-Detachable 52mm (diameter) Vane Head
-1.8 meters coiled cable/back mounting screw for long extension
-Lower Power Consumption (6mA)
-Max/Min/Ave and Data hold function
-RS-232C interface
-Optional portable thermal printer
-Air Temperature Measurement
Share on :
Similar Products
Manufacturer: TES
Model: TES-1341
Original: Taiwan
Features
-Ai...
Manufacturer: TES
Model: TES-1341
Original: Taiwan
Features
-Air flow volume measurement
-Temperature and humidity measurement
-Calculate dew point temperature, wet bulb temperature, wind chill temperature, humidex temperature and heat index temperature
-Data hold & maximum/minimum function
-Manual and automatic data memory and read function (5 x 99 sets)
-Triple LCD display with backlight
-Telescoping probe
-USB interface
-Air Velocity Range: 0.1 to 30.0 m/s
-Air Velocity Accuracy: ±3% rdg. ±1% f.s.
-Air Flow Volume Range: 0 to 999900 m3/min
-Air Flow Volume Accuracy: ±3% rdg. ±1% f.s.
-Humidity Range: 10 to 95% RH
-Humidity Accuracy: ±3% RH (30-95% RH); ±5% RH (10-30% RH)
-Temperature Range: -10 to 60°C
-Temperature Accuracy: ±0.5°C
-Wet Bulb Temperature Range: 5 to 60°C
-Dew Point Temperature Range: -15 to 49°C
-Power Supply: 6 x AAA batteries
-Dimensions/Weight: 135 x 72 x 31mm/400g (including probe)
Range of Temperature:
Range(°C): 0-45.0, Resolution: 0.2, Accuracy: ±1.0
...
Range of Temperature:
Range(°C): 0-45.0, Resolution: 0.2, Accuracy: ±1.0
Range(°F): 32.0-113.0, Resolution: 0.36, Accuracy: ±1.8
Flow: (Auto-range, CMM: 0 - 45.00 m/s, CFM: 0 -8800 ft/min)
CFM (ft /min): Range: 0 - 999900, Resolution: 0.001 - 100, Area: 0.001- 9999
CMM (m /min): Range: 0 - 999900, Resolution: 0.001 - 100, Area: 0.001- 9999
Bearing: Sapphire jewel bearing
Temperature sensor: K-type thermocouple
Mounting Nut: 1/4" x 20
Operating Temperature: Meter: 0°C ~ 50°C (32°F ~ 122°F)
Vane: 0°C ~ 60°C (32°F ~ 140°F)
Operating Humidity: Less than 80% RH
Operating Pressure: 500 mB ~ 2 Bar
Storage Temperature: -40°C ~ 60°C (-40°F ~ 140°F)
Range of Temperature:
Range(°C): 0-45.0, Resolution: 0.2, Accuracy: ±1.0
...
Range of Temperature:
Range(°C): 0-45.0, Resolution: 0.2, Accuracy: ±1.0
Range(°F): 32.0-113.0, Resolution: 0.36, Accuracy: ±1.8
Flow: (Auto-range, CMM: 0 - 45.00 m/s, CFM: 0 -8800 ft/min)
CFM (ft /min): Range: 0 - 999900, Resolution: 0.001 - 100, Area: 0.001- 9999
CMM (m /min): Range: 0 - 999900, Resolution: 0.001 - 100, Area: 0.001- 9999
Bearing: Sapphire jewel bearing
Temperature sensor: K-type thermocouple
Mounting Nut: 1/4" x 20
Operating Temperature: Meter: 0°C ~ 50°C (32°F ~ 122°F)
Vane: 0°C ~ 60°C (32°F ~ 140°F)
Operating Humidity: Less than 80% RH
Operating Pressure: 500 mB ~ 2 Bar
Storage Temperature: -40°C ~ 60°C (-40°F ~ 140°F)
Power Consumption: Approx. 3 mA
-
Vane anemometer with permanently installed 30 mm vane
-
Measu...
-
Convenient, quick volume flow measurement
-
Accurate measurem...
. Suitable for high wind speed measurement
• Differential pressure, Stagnation pressu...
. Suitable for high wind speed measurement
• Differential pressure, Stagnation pressure and Static pressure measurement
• Instant/Avg/ 2/3 V max flow measurement
• Velocity m/s, ft/min
• Temperature, Humidity & Atmospheric measurement
• Calculate Dew point temperature, Wet bulb temperature, Wind chill temperature, Humidex temperature and Heat index temperature.
• Data hold & Maximum / Minimum / Average function
• Manual data memory and read function: 99 sets
• Auto data memory: microSD card (3142U)
• USB interface (3142U) .
Featured Products
50.000 30.000 JOD
20.000 15.000 JOD
15.000 12.000 JOD