Manufacturer: TES
Model: CM-01
Original: Taiwan
- High Resolution DC/AC 1...
Manufacturer: TES
Model: CM-01
Original: Taiwan
- High Resolution DC/AC 10mA
- 23mm Large Jaw Diameter
- One Touch Zero for DCA adjustment
- Large 3 3/4 Digits LCD (4032 Counts)
- Fast Analog Bargraph Display
- Max/Min, Data Hold
- 600Vrms Overload Protection for Ohm Measurement
- AC/DC Current: 40A/0~150A/150~200A
-AC/DC Voltage: 400V
- Resistance: 40~400 Ω (beep if < 40.0Ω )
- Frequency: 1~100KHz
Manufacturer: TES
Model: CM-03
Original: Taiwan
-10uA Ultra High Resoluti...
Manufacturer: TES
Model: CM-03
Original: Taiwan
-10uA Ultra High Resolution on 40mA range
-30mm Large Conductor Diameter
-ACA 5 Range (40mA, 400mA, 4A, 40A, 60A)
-Fast bargraph display (30 times/sec.)
-Max/Min, Data Hold function
-Relative measurement
-AC Current: (+/-1.0% rdg +/-3dgts) 40m/400m/4A/40A/60A
-AC Voltage: 400V
-Resistance and Continuity: 40~400 Ω
Manufacturer: TES
Model: Prova 200A
Original: Taiwan
-Features: I-V curve...
Manufacturer: TES
Model: Prova 200A
Original: Taiwan
-Features: I-V curve test for solar panel/module
-Max. solar panel power (Pmax) search by auto-scan: 60V, 6A
-Best Resolution: 1mV, .01mA
-Manual single point I-V test
-Max. voltage (Vmaxp) at Pmax
-Max. current (Imaxp) at Pmax
-Voltage at open circuit (Vopen)
-Current at short circuit (Ishort)
-I-V Curve with cursor to display each data point
-Efficiency (%) calculation of solar panel
-Solar panel area setting: 0.001m2 ~ 9999m2
-Standard light source setting: 10W/ m2 ~ 1000W/ m
-Communicate with PC with USB cable
-Min. power setting for alarm function
-Built-in calendar clock
-Built-in battery charging circuit
-Rechargeable lithium batteries and AC adaptor
-Memory Size: 100 records
- Large LCD with backlight
Application:
- Quality Control in the production line, warehouse, or site of installation
- Identify the solar power system requirement
- Maintenance of solar panels
- Verify the best installation angle of solar panels
Manufacturer: TES
Model: Prova 700
Original: Taiwan
-Max. Test Current: 5...
Manufacturer: TES
Model: Prova 700
Original: Taiwan
-Max. Test Current: 5A
-Four Terminal Kelvin measurement.
-Best resolution 1 µΩ .
-Basic accuracy 0.25%.
-Manual or Auto Range.
-Measurement of resistive and inductive materials.
-Readings Hold function.
-Cable length measurement
-Large LCD (5-digit) with backlight
-Low battery (voltage) alarm.
-Low Power consumption
-Rechargeable lithium batteries and AC adaptor
-RS232C (to USB bridge) cable
-Built-in calendar clock
-Built-in batteries charging circuit
Application
-Coil resistance of Electric motor
-Contact resistance of Switch and Relay
-Resistance of Bus bar, Breaker, Fuse, Inductance and Shunt
Manufacturer: TES
Model: AVM-305
Original: Taiwan
Ideal for
-Venti...
Manufacturer: TES
Model: AVM-305
Original: Taiwan
Ideal for
-Ventilation survey
-Air-conditioning / Heating
-Sports recreational
Features
-Sensitive for low air velocity
-Ergonomic Design
-Detachable 52mm (diameter) Vane Head
-1.8 meters coiled cable/back mounting screw for long extension
-Lower Power Consumption (6mA)
-Max/Min/Ave and Data hold function
-RS-232C interface
-Optional portable thermal printer
-Air Temperature Measurement
Manufacturer: TES
Model: Prova 2003
Original: Taiwan
- DC 2500A, AC 2100A...
Manufacturer: TES
Model: Prova 2003
Original: Taiwan
- DC 2500A, AC 2100A
- ϕ 55mm, Bus Bar 65mmx24mm
- Auto Range A, V, Ω, Hz
- DCA One Touch Zero
- Diode Test
- Continuity with buzzer
- Max/Min/Hold
- Relative Measurement
- Large 3 3/4 Digits LCD
- Fast bargraph display
- Resistance measurement
- Current: (AC/DC)
DC~400A/2500A
AC~400A/2100A
- Current Analog Output: 400A/2,100A(1mV/A)
- Voltage: (AC/DC)
DC~400m/4V/40V/400V/600V
AC~4V/40V/400V/600V
- Frequency: (Hz) 1~100KHz
Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W
True RMS value (V123 and 1123)
Active Pow...
Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W
True RMS value (V123 and 1123)
Active Power (W, KW, MW, GW)
Apparent and Reactive Power (KVA, KVAR)
Power Factor (PF), Phase Angle (0)
Energy (WH, KWH, KVARH, PFH)
• AC Current (0.04A to 6000A) and Voltage measurement: True RMS, Auto Range.
• Capable of analyzing IT standby power consumption to the maximum demand of a factory
Display of 35 Parameters in One Screen (3P4W)
• Programmable CT (1 to 600) and PT (1 to 3000) Ratios
• Display of Overlapped Voltage and Current Waveform
Average Demand (AD in W, KW, MW)
• Maximum Demand (MD in KW, MW, KVA,
MVA) with Programmable Period
Harmonic Analysis to the 99th Order
• Display of 50 Harmonics in one Screen with Waveform
• Display of Waveform with Peak Values (1024 Samples / Period)
• Analysis of Total Harmonic Distortion (THD-F)
• Graphic Phasor Diagram with 3 Phase System Parameters
• Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%)
• DIP, SWELL, and OUTAGE are included in transient events.
• 3 Phase Voltage or Current Unbalance Ratio (VUR, IUR)
• 3 Phase Voltage or Current Unbalance Factor (d0%, d2%)
• Calculated Unbalanced Current through Neutral Line (In)
512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system)
Output of Waveform, Power Parameters and Harmonics at Command
Large Dot Matrix LCD Display with Backlight
• Software to work with PC via Optical Isolated RS-232C to USB Interface
Conductος δίτοι
Built-in timer and calendar for data logging
Manufacturer: TES
Model: Prova 123
Original: Taiwan
- 4-20mA (1KΩ l...
Manufacturer: TES
Model: Prova 123
Original: Taiwan
- 4-20mA (1KΩ load, 24V Loop Supply)
- 0~100.00mV, 0~1.0000V, 0~10.000V
- K.J.E.T. Thermocouples
- Frequency 1~62,500 Hz
- 0.025% Basic Accuracy
- Easy Key-pad Operation
- Easy Step & Auto Ramp Functions
- 0~20mA, 0~24mA selectable
- 0~100% Input (mA, mV, V)
- Beeper warning when output is open (mA) or short (mV, V)
Manufacturer: TES
Model: TES-3092
Original: Taiwan
- Non-Contact Ground R...
Manufacturer: TES
Model: TES-3092
Original: Taiwan
- Non-Contact Ground Resistance Measurement
- No Auxiliary Electrode Needed
- Jaw Diameter 23mm
- 0.2mA~30A True RMS
- 116 Sets of Memory
- Programmable High and Low Alarm
- Programmable Data Logging
- Data Logging interval:1 to 255 sec
- Ground Resistance:
- 0.025~0.250/0.251~1.000/ 1.001~10.00/10.01~50.00/ 50.01~100.0/100.1~200.0/ 200.1~400.0/400.1~600.0/ 600.1~1500
- Ground/Leakage Current: (50/60Hz, True RMS ) 0.300~1.000/1.00~10.00/ 10.0~100.0/100~1000mA/ 0.20~4.000A/ 4.00~30.00A